cm
cm

0 cm = going from the step formula.

Step formula per DIN 18065: 2 × rise + going = 63 cm. Target rise: 17.5 cm.

Number of steps

16steps

16

For a 280 cm floor-to-floor height, 16 steps fit: rise 17.5 cm, going 26.67 cm, pace 61.67 cm – DIN 18065 is met.

s 17.5 cma 26.67 cm400 cm280 cm
Rise (s)DIN-compliant (14–20 cm)
17.5 cm
Going (a)DIN-compliant (23–37 cm)
26.67 cm
Pace measurementDIN-compliant (59–65 cm)
61.67 cm

Step-count variants

How this was calculated
s = 280 cm ÷ 16 = 17.5 cm
a = 400 cm ÷ (16 − 1) = 26.67 cm
Pace measurement = 2 × 17.5 cm + 26.67 cm = 61.67 cm

The number of steps follows from the target rise of 17.5 cm; the going from run ÷ (steps − 1). With a fixed run, one step more or less often restores DIN compliance.

Plan further:Concrete calculatorScreed calculatorInsulation calculator